01

9413X Series Weight-Loaded Pressure Conservation Vent

Weight-Loaded Pressure Conservation Vent

Download Datasheet ↵

Shand & Jurs 9413X Series Weight-Loaded Pressure Conservation Vent

For terminal operators, tank-farm engineers, and emissions specialists, the Shand & Jurs 9413X Series weight-loaded pressure conservation vent protects atmospheric tanks against routine thermal and liquid-movement pressure excursions while keeping continuous vapor loss low.

Unlike free vents that communicate openly with atmosphere and lose product on every breathing cycle, the 9413X holds tank pressure against a weight-loaded, diaphragm-sealed pallet and opens only when the set pressure is reached, reducing evaporative loss and VOC emissions.

Peripheral and center-stem pallet guidance promotes smooth lift and consistent reseating during cycling. An air-cushion-seated FEP diaphragm resists sticking from ice or gum formation. Optional Expanda-Seal technology tightens the seal as pressure approaches setpoint, holding leakage under 0.5 SCFH at 95 percent.

Three configurations cover open (94130), closed outlet-larger-than-inlet (94131), and equal-size closed (94132) installations. Sizing is supported by WinSize software, sized per API 2000.

Shand & Jurs 94130
Shand & Jurs 9413X Series Weight-Loaded Pressure Conservation Vent
02

Features

Guided Pressure Pallet

Peripheral and center-stem guidance keeps the pallet aligned through repeated cycling, promoting smooth lift and consistent reseating during routine breathing.

Air-Cushion FEP Diaphragm

Standard FEP diaphragm resists adhesion from ice or gum formation, supporting positive sealing and predictable blowdown under cyclic service.

Expanda-Seal Option

Optional self-energizing seal tightens as pressure approaches setpoint, holding leakage under 0.5 SCFH at 95 percent versus roughly 1.0 SCFH at 90.

Open or Pipe-Away Discharge

Three configurations cover open atmospheric discharge (94130), closed outlet-larger-than-inlet (94131), and equal-size closed (94132) for vapor-recovery routing.

Wide Weight-Loaded Range

Standard 0.5 oz/in squared setting, configurable up to 24 oz/in squared, covers a broad range of low-pressure tank operating envelopes.

Global Flange Compatibility

ANSI 125/150, EN1092-1 PN16, and JIS 10K drillings fit regional tank-nozzle standards without adapter plates or custom machining.

Applications

  • Fuel Terminals: Protects gasoline, diesel, and jet-fuel storage against thermal breathing excursions while minimizing continuous vapor loss on high-value, high-volume inventory.
  • Chemical Storage: Controls pressure on solvent, specialty chemical, and intermediate tanks where routine vapor release would carry VOC, odor, or product-value penalties.
  • Nitrogen-Blanketed Tanks: Holds blanketing gas near setpoint, reducing nuisance venting that drives up nitrogen consumption and risks oxygen ingress during relief cycles.
  • Vapor Recovery Systems: Closed 94131/94132 configurations pipe routine breathing directly to a vapor-recovery header rather than atmosphere, preserving recovered product and reducing emissions.
  • VOC-Regulated Facilities: Expanda-Seal option limits fugitive emissions near setpoint, supporting reduced-emission operating programs at terminals and chemical sites.
  • Corrosive Vapor Service: 316 stainless steel body and alternate diaphragm materials extend compatibility for acid, caustic, and aggressive chemical vapor handling.
03

Specifications

Parameter

Specification

Device Type

Weight-loaded pressure conservation vent

Models

94130 (open), 94131 (closed, outlet > inlet), 94132 (closed, equal-size)

Standard Set Pressure

0.5 oz/in² (0.86 in. W.C.)

Maximum Setting

24 oz/in²

Expanda-Seal Minimum Setpoint

1.5 oz/in² (consult factory for lower)

Leakage Performance

  • Standard pallet: <1 SCFH air at 90% of setpoint.
  • Expanda-Seal: <0.5 SCFH at 95% of setpoint.

Sealing Method

Air-cushion seated diaphragm

Loading Method

Weight loaded

Nominal Sizes

2″, 3″, 4″, 6″, 8″, 10″, 12″

Flanged Connections

ANSI 125/150 • EN1092-1 PN16 • JIS 10K (FF/RF per material)

Temperature Range (Body)

Aluminum −65°F to +250°F; 316 SS −65°F to +350°F; Carbon Steel −20°F to +350°F

Temperature Range (Diaphragm)

FEP −65°F to +400°F (standard); FKM −15°F to +400°F; NBR −40°F to +250°F; PFA −65°F to +500°F

Sizing Basis

API 2000 (capacity)

Body and Seat Materials

Cast Aluminum, Cast Steel, or 316 Stainless Steel (seat field-replaceable in Al or 316 SS)

Pallets

Aluminum or 316 Stainless Steel

Diaphragm

FEP (standard); FKM, NBR, or PFA available

Weights

Lead or 316 Stainless Steel (by setting range)

Hardware

Stainless Steel (316 SS for severe service)

Options

Expanda-Seal pallet, closed vent / pipe-away cover, All Weather Teflon coating, insulation jacket, steam jacket, ATEX certification

Get a Quote
2026 COST ESTIMATE

Contact Support

If you have questions not covered here, please contact the Cognesense support team for assistance.

Contact Us ↵

What is the difference between the 94130, 94131, and 94132?

−

All three are weight-loaded pressure conservation vents built on the same sealing platform. The 94130 is an open vent with a weather hood discharging to atmosphere. The 94131 is a closed vent with an outlet larger than the inlet, configured for pipe-away routing. The 94132 is a closed vent with equal-size inlet and outlet connections. Choose the model based on how you are discharging routine breathing: atmosphere, or piped into a vapor-recovery or control-system header.

When should Expanda-Seal be specified?

+

Expanda-Seal is recommended where routine vapor loss near setpoint is a concern — VOC-regulated sites, nitrogen-blanketed tanks where leakage increases gas consumption, and high-value product storage. Expanda-Seal is available on configurations with a setpoint of 1.5 oz/in² or higher. It holds leakage under 0.5 SCFH at 95% of setpoint, compared with roughly 1.0 SCFH at 90% for a standard pallet.

How is the 9413X sized?

+

Relief capacity is sized per API 2000 (Venting Atmospheric and Low-Pressure Storage Tanks). Shand & Jurs WinSize (EZ-Flow) software walks specifying engineers through flow, pressure, and size selection and produces documentation suitable for engineering review.

What flange standards are available?

+

The 9413X supports ANSI 125/150, EN1092-1 PN16, and JIS 10K drillings (flat-face or raised-face per material), so the same model platform fits North American, European, and Asian tank installations without adapter plates.

What body and diaphragm materials are available for corrosive service?

+

Body materials include cast aluminum, cast steel, and 316 stainless steel. Alternate diaphragm elastomers — FKM, NBR, and PFA — extend chemical and temperature compatibility beyond standard FEP. Field-replaceable seat rings (in Al or 316 SS) support in-place maintenance.

Is ATEX certification available?

+

Yes. ATEX certification is available as an option for classified European explosive atmospheres. Insulation jacket, steam jacket, and an All Weather Teflon coating are also offered for cold-weather, heated-service, or outdoor exposure requirements.

How does this vent fit into a closed-vent or vapor-recovery system?

+

The 94131 and 94132 closed configurations pipe routine tank breathing directly into a vapor-recovery or control-system header rather than venting to atmosphere. Paired with an emergency vent and, where required, a flame arrester, the 9413X forms part of a complete atmospheric-tank protection stack.

Summary

With over a century of tank-safety heritage inside Cognesense, the Shand & Jurs 9413X Series weight-loaded pressure conservation vent protects atmospheric storage tanks against routine thermal and vapor-movement excursions while keeping continuous vapor loss low. Guided pallet geometry, diaphragm sealing, and optional Expanda-Seal technology support stable setpoints, reduced emissions, and predictable reseating. With API 2000 sizing, WinSize support, and global flange compatibility, the 9413X fits within Cognesense’s tank-safety portfolio to help terminals measure, monitor, and protect what matters most.